Fingerprint and Biological Evidence Visualization System

The Fingerprint and Biological Evidence Visualization System is the latest product developed by laserlistening4u for targeted extraction of forensic fingerprint and biological evidence using Aggregation-Induced Emission (AIE) fluorescence technology. This device utilizes laserlistening4u’s proprietary targeted fluorescence design, where the AIE-induced luminescent reagents are atomized and sprayed onto the forensic samples. The cationic AIE molecules interact electrostatically with anionic biomacromolecules, leading to the aggregation of AIE molecules on the side chains of amino acids. As a result of the AIE effect, significant fluorescence is generated at the amino acid sites, while the background areas do not aggregate and do not exhibit significant fluorescence, thereby achieving maximum contrast under blue light excitation.

The AIE molecules have high sensitivity for biological detection due to their low background, non-toxicity, and strong photostability.

Fingerprint and Biological Evidence Visualization System
Fingerprint and Biological Evidence Visualization System
Compact and portable, easy to operate

The complete set of the The Fingerprint and Biological Evidence Visualization System weighs approximately 2 kilograms, requiring no specialized training and can be used immediately.

Instant development, high efficiency
Physical adsorption, non-destructive to evidence

The Fingerprint and Biological Evidence Visualization System does not chemically react with the evidence, ensuring that subsequent evidence profiling and identification are unaffected.

Equipment Principle

The Fingerprint and Biological Evidence Visualization System primarily utilizes Aggregation-Induced Emission (AIE) fluorescence technology. It is the latest product developed by laserlistening4u for the extraction of forensic fingerprint and biological evidence. The reagents used in this product employ laserlistening4u’s unique targeted fluorescence design. Specifically, AIE reagents are atomized uniformly and finely, and they quickly adsorb and aggregate with amino acids and lipids present in sweat components. Under excitation from a blue laser, the aggregated AIE molecules emit bright orange fluorescence.

This method enables the rapid visualization of fingerprint traces, palm prints, and contact traces within seconds.

Camera Filter

Instant and Efficient Visualization

Fluorescence of fingerprint can be visualized within 5-30 seconds, eliminating the need for long waiting times.

Non-Destructive Sample Collection

Ensuring that there is no chemical reaction with the collected evidence, preserving its integrity for subsequent analysis and identification.

Wide Application Range

Suitable for the visualization of non-permeable surface latent fingerprints, palm prints, and fresh sweat fingerprints, providing an alternative to conventional methods like fuming and powdering.

Long Battery Life

Equipped with a 6600mAh battery, the device can operate for up to 2 hours on a single charge, ensuring sufficient usage time in the field

Enhanced Safety Measures

Incorporates safety features such as non-toxic reagents and robust containment mechanisms to ensure the safety of users and minimize potential hazards.

Reliable and Durable

Built with high-quality materials and designed to withstand demanding field conditions, ensuring long-lasting performance and reliability.

Why Choose Our Solutions?

Here are some more compelling reasons for clients to choose our  product

High Sensitivity and Accuracy

The Fingerprint and Biological Evidence Visualization System utilizes advanced AIE technology, resulting in high sensitivity and accuracy in detecting and visualizing fingerprint and biological evidence. This ensures reliable and precise results for forensic analysis.

time
Time-Efficient Operation

Enables quick and efficient sample collection and visualization, saving valuable time during crime scene processing and investigation.

user-circle
User-Friendly Interface

The Fingerprint and Biological Evidence Visualization System features an intuitive and user-friendly interface, making it easy for investigators of varying skill levels to operate and navigate. This minimizes the learning curve and enables efficient use of the device.

Rapid and Real-time Results

The Fingerprint and Biological Evidence Visualization System offers fast and real-time visualization of fingerprints and biological evidence, allowing investigators to quickly gather crucial information and make prompt decisions during crime scene investigations.

Scientifically Validated Results

The effectiveness and reliability of the product have been scientifically validated through rigorous testing and research. This ensures that clients can trust the accuracy and credibility of the results obtained using the device.

Versatile Integration Capabilities

The Fingerprint and Biological Evidence Visualization System is designed with compatibility in mind, allowing seamless integration with existing forensic equipment and laboratory workflows. This ensures smooth adoption and enhances the overall efficiency of forensic processes.

Technical Parameters

Host Parameters:

  • Dimensions: 18cm6cm4cm
  • Weight: 0.5kg (including reagent box)
  • Uniformity of light spot: 90%
  • Visualization time: 5 seconds to 20 seconds (A4 paper area)
  • Battery capacity: 6600mAh
  • Battery life: 2 hours
  • Charging interface: Supports TYPC-C charging port, compatible with mobile phone charging
  • Reagent box capacity: 20ml

Laser Light Source Parameters:

  • Laser power: 5W
  • Output power: 3.5W
  • Laser wavelength: 445nm±2nm

Atomization Reagent Technical Specifications:

  • Atomization efficiency: 0.3ml/min (continuous atomization of one reagent box for 120 minutes)
  • Median particle size of atomization: Approximately 3μm

Other Parameters:

  • Replaceable reagent box
  • Connection between the host and handle: Rotary connection; the handle is detachable, and the host can rotate 360° around the axis. The handle can be opened and used as a tripod, facilitating single-person photography and evidence collection. The tripod can be moved left and right.

Configuration List

No.NameParametersQuantityNote
1Laser/Atomization Host5W1 
2Mobile Fluorescence Accessory 1 
3Fluorescence Filter for Camera 1 set 
4Integrated Eye Protection Goggles 2 pairs 
5Portable Power Bank and Accessories 1 set 
6Portable Handle/Tripod 1 
7Targeted Testing Reagent50ml2 bottles 
8Atomization Head 2 
9Instruction Manual 1 copy

Application Cases

Where our product can be used on

on the bottle surface

on the brick surface

on the cupboard surface

On the surface of door frame

On the hard paper surface

On the surface of Wall